There is a leak coming from the immersion element of my Edel 200/270 cylinder. What do I do?


Applicable to models:  EDL200-630RF, EDL270-630RF, EDL200-630, EDL270-630 

 

Issue:  Water appears to be coming from the element at the bottom of the cylinder around the immersion element. 


Action

In Guarantee -  Service visit required, see below additional help link. Please attach pictures of the leak, data label and the cylinder in situ. 


Out of Guarantee - A Service engineer should safely isolate the cylinder from the mains supply, drain down the cylinder and remove the immersion element for inspection. The rubber o-ring seal should be inspected and if believed to be suspect, changed out. This is part X-B1657452 (Element O-Ring). Alternatively, the entire 1.2kW element & O-Ring assembly is part number X-B4992886. 

See additional help link below for list of out of guarantee service agents.


When re-fitting the immersion element, it should be tightened to a torque of 70 Nm.

 

X-B1657452 (O-Ring only)



X-B4992886 (1.2kW Element AND O-Ring)





Require additional help? Please follow link below

https://glendimplexservice.freshdesk.com/a/solutions/articles/79000136321


Was this article helpful?

That’s Great!

Thank you for your feedback

Sorry! We couldn't be helpful

Thank you for your feedback

Let us know how can we improve this article!

Select at least one of the reasons
CAPTCHA verification is required.

Feedback sent

We appreciate your effort and will try to fix the article