ERR. 04 error is displayed on the Edel cylinder. What does this mean?

This means the Edel had detected one of the following possible issues:
- Discrepancy between the evaporator & water temperatures
 - The evaporator & water temperature sensors might be misreading or accidentally swapped around.

An engineer’s visit will be needed to establish root cause & repair.

Take following parts (applies to all sizes):
X-B1244575 (Hot water temp probe 10kOhm 1200mm)
X-B4993072 (Evap temp probe 10kOhm 900mm)
X-B1244090 (Air temp probe 10kOhm 460mm)
X-B1244096 Main PCB


Note: It it may not be possible to ask for the "Elec Mode" backup to run if there is an ERR04 fault is actively present, as the Edel is not certain what the real current hot water temperature is at present.

 

Require additional help? Please follow link below

https://glendimplexservice.freshdesk.com/a/solutions/articles/79000136321





Applicable Models:

EDL170-520, EDL170-520RF, EDL200UK-630, EDL200UK-630RF, EDL270UK-630, EDL270UK-630RF

Was this article helpful?

That’s Great!

Thank you for your feedback

Sorry! We couldn't be helpful

Thank you for your feedback

Let us know how can we improve this article!

Select at least one of the reasons
CAPTCHA verification is required.

Feedback sent

We appreciate your effort and will try to fix the article