Clock error is displayed on the Edel cylinder. What does this mean?

This is an error with the display or main PCB accessing the onboard timeclock function. 

The user should try setting the current date & time by pressing the clock button on the display, then setting the date/time correctly. 

Edel Clock Nov 2019 from GDHV Digital on Vimeo.


If the error persists, a competent engineer should isolate the mains supply as per safe isolation procedure, then change the display and/or Main PCB to resolve the issue. Both display & PCB should be taken to the job.

500002222 170l cylinder display & cable
X-B4992570 200 & 270L cylinder display & cable
X-B1244096  Main PCB (all 3 sizes) 


The compressor should still work providing the timer is set to 0000-2400 COMF mode (see page “Programming” section in the user manual) but if the compressor does not run, electric backup mode can be selected:
 

To switch on the backup immersion, search knowledge base “My Edel hot water cylinder has stopped heating the water. How do I get hot water via backup?”



Require additional help? Please follow link below

https://glendimplexservice.freshdesk.com/a/solutions/articles/79000136321




Applicable Models:

EDL170-520, EDL170-520RF, EDL200UK-630, EDL200UK-630RF, EDL270UK-630, EDL270UK-630RF